Medical Alarm Surveys
A Health Care Article Contributed by Ajitha Nair
Medical Alarm Evaluations
With a flood of medical alarms in the market and the increase in subscriber data base, the question of quality medical alarms and bringing them all under an international standard is gaining ground. It has been observed that the signals used in these alarms at best can be described as disturbing and distracting to both the patient as well as the care giver. Hence a new international standard ISO/IEC 60601 has been arrived at to control the proliferation of such disturbing signals.
This new international standard replaces the old one ISO 9703-1:1992 for respiratory care alarm signals as well as visual alarm signal standard ISO 9703-3:1998.
Although care has been taken in this new standard to retain some of the beneficial and commonly used indicators such as a high priority alarm requiring immediate attention by a clinician having a red indicator with a flashing frequency of 1.4 to 2.4Hz, a medium priority alarm requiring immediate response having a yellow indicator color and flashing frequency of 0.4 to 0.8Hz and a low priority alarm requiring awareness of the situation using a constant yellow indicator.
Reason to re-Evaluate Medical Alarm Signals
The Massachusetts Institute of Technology and the Laboratory of Computer Science having recently undertaken an exhaustive study on medical alarm signals concluded that of the 2942 medical alarms they analyzed, 86% of them were false alarms and 6% of them were medically irrelevant. Of the actual 12 alarms only one turned out to be a true medical alarm.
This study prompted the invention of intelligent medical alarm which have the capability of providing valuable information to the medical practitioner revealing an overview of logical decisions, alarm conditions criteria for escalations in condition and monitored information of the patient's different variables such as blood pressure, heart rate, etc. so as to utilize optimum medical care and save valuable medical care manpower.
These utilize radio transmitted change of a monitored variables to determine the priority level.
Security Concerns in Medical Alarm Systems
The problem of security and safety is also appropriately addressed into the new standard. The basic security problems being the user configured or operator configured default alarm settings which may get interfered due to other signals to emit a false alarm or an unwanted alarm.
This problem has been outgrown in the intelligent medical alarm systems using passwords, voice recognition softwares and finger printing etc. The other problem of medical alarm interfering during medical surgical procedures have been addressed through guidelines for alarm silencing. Remote medical alarm signals interfering with other electronic or medical equipments are also addressed under this new standard.
Benefits of New Standard in Medical Alarm
The major benefit to the health care personals will be of that of less distraction and disturbance and clearly recognized uniform and visual auditory signals can help them to adapt easily to the gravity of the situations. Many other critical problems that arise during complicated medical procedures due to interference of medical alarms such as problems in ionizing, photo-therapy, radiology, ultrasound, and radio frequency indicators can be effectively addressed under this new standard.



