![]() |
|
![]() |
info about Universal Frequency Counter, Agilent Universal Frequency Counter, TF830 universal frequency counter, 3.0GHz Universal Counter, UZ 2400 Universal Counter, FC2500 Universal Frequency CounterPM 6685 Universal Frequency CounterInternet Epoch | Home Live | Look Faq | The Fluke PM 6685 Frequency Counter brings calibration lab accuracy to field
measurements Cal lab performance in the field Built in capabilities simplify tricky measurements The PM 6685's built-in intelligence eliminates a lot of button pushing. Just plug it in, and it automatically selects optimum trigger level and input sensitivity for excellent noise immunity. Analog bar graph The analog bar graph displays signal strength and input sensitivity to assist instrument setup and RF tuning applications. 300 MHz basic input range; options for 1.3 GHz, 2.7 GHz and 8 GHz. Measurement functions Frequency, Burst Frequency, Period A, Ratio A/E C/A, Pulse Width A, Duty Factor, Totalize A. Auxiliary functions External Arming, External Gate, Nulling/Frequency Offset. Options & accessories External Reference Multiplier (1,5,10 MHz), GPIB Interface, Battery Unit. For more details about pm universal frequency counter from us.fluke.com Agilent 53132A Universal Frequency CounterFeatures: Agilent frequency counter include
frequency, frequency ratio, time interval, rise/fall time, phase, duty cycle,
positive/negative pulse width, totalize, peak voltage, time interval average and
time interval delay. Description For applications requiring higher resolution, the 53132A offers the same features and functions as the 53131A, with up to 12 digits/sec frquency/period resolution and 150 ps time interval resolution. In addition, the 53132A offers advanced arming modes for time interval measurements. The Agilent 53132A universal frequency counter has frequency resolution of 12 digits per second, 150 ps time interval resolution and a complete set of test and analysis features. The unit comes with two 225 MHz channels, and you can choose an optional third channel that measures up to 3 GHz, 5 GHz or 12.4 GHz. Source from tequipment.net TF830 universal frequency counterDescription and Specifications A wide range of functions In addition to frequency counter the TF830 offers period measurement, frequency ratio, pulse width measurement and event counting. Pulse width measurements can be made from rising to falling edge or vice versa. High resolution reciprocal counting The TF830 uses the reciprocal frequency counting technique to achieve high
resolution at all frequencies. Reciprocal counting involves synchonised multiple
period measurements followed by computation of the reciprocal value. This results
in high resolution measurements regardless of the signal frequency and eliminates
the +/-1 input cycle errors of a conventional frequency counter. To ensure maximum flexibility the TF830 can operate from disposable batteries, rechargeable batteries or AC line. Low power circuitry is combined with an LCD display to give up to 200 hours of operation from alkaline batteries. Remote control and read-back The TF830 is available with the option of an addressable RS-232 interface.
This can be used as a normal RS-232 interface or as part of a multi-instrument
setup under the TTi ARC system. Source from tti-test.com
Craft Arts By Mortgage Banking Service Look Faq Antique Way Home Live Child Healths 5328 universal frequency counterThe following description is for the model 5328A frequency counter only. Other fequency counters use different techniques to derive the displayed frequency. The outputs available vary from frequency counter to counter. For further information on other types of counters and their uses, refer to EIMB, Test Equipment, NAVSEA 0967-LP-000-0040. The model 5328A is a portable, solid-state electronic frequency counter. It is used to precisely measure and display, using a nine-digit LED readout, frequency, period, period average, time interval, time interval average, and ratio of electronic frequency signals. This frequency counter can also provide a 1-MHz and 10-MHz output signal through the back-panel BNC. Q-6. What frequencies are provided through the back-panel BNC? The model 5328A frequency counter can be divided into four major internal subsections: the main frequency counter section, input section, power supply, and interface bus section. Additionally, two separate (front panel) input channels provide for time interval measurements. Each channel has an attenuator, trigger slope selector, level control, ac or dc coupling, and an oscilloscope marker output. A third input channel is provided to allow the measurement of 30 MHz to 500 MHz with a maximum input of 5 volts rms with a fused-protected connection. Front-panel controls are provided for you to do the function selection, frequency resolution, sample rate, and reset display. Also, a push-button control on the front panel allows the unit to be used in the operational or standby mode (power applied to the crystal oven to eliminate warm-up). Rear-panel connectors provide the gated output frequencies and an input for an external frequency standard. A detachable front cover is used to store accessory cables and connectors. Source from tpub.com UZ 2400 Universal Counter
Special features of the UZ 2400 include a high basic accuracy of 10-10 (short-term)
due to the quartz oven-oscillator, and a long-term stability of 10-8 over 24 hours.
UZ 2500 Universal CounterThe UZ 2500 universal frequency counter is yet another addition to GRUNDIG
electronics range of innovative service measuring instruments. Like the others
in the range, In addition to frequency measurement and counting, periods and various frequency
response ratios can be determined and pulse widths measured. Get more universal frequency counter products from ferner.se |
3.4Ghz 8 Digit Universal Frequency CounterFeatures More details from aplab.com FC2500 2.5 GHz Universal Frequency CounterThe FC 2500 is a microprocessor controlled portable universal frequency counter in a compact low cost instrument. The design incorporates an LED back light 16x2 LCD giving clear easily read characters. The frequency range is 5 Hz to 2.5 GHz and measurement functions include frequency, period, ratio, pulse width and count. The instrument uses a reciprocal counting technique to provide high resolutions, normally 7 significant digits of answer are produced per second of measurement time. A temperature controlled crystal oven provides high measurement accuracy and stability. ¨ Simple operation |